7- Technical data
For vaccine growth medium.
Dehydrator AV500L | Dehydrator AV1500L | Dehydrator AV3000L | Dehydrator AV6000L | |
Capacity | ||||
Processed volume per batch (liters) | 500 | 1700 | 3800 | 6800 |
Estimated number of processed eggs par batch (eggs) | 10000 | 30000 | 75000 | 130000 |
Time per batch (hours) | 5 to 7 | 10 to 14 | 12 to 15 | 12 to 17 |
Time to download after process (minutes) | 10 | 15 | 15 | 20 |
Temperature of the entire product during dehydration |
> 80°C 4 hours |
> 80°C 4 hours |
> 80°C 6 hours |
> 80°C 6 hours |
Humidity rate of the product after processing | around 20% of humidity | |||
Utilities | ||||
Installed electrical power (KW): | 8 | 20 | 30 | 42 |
Estimated electrical power used during cycle (KWH) | 4 | 10 | 18 | 25 |
Installed natural gas |
50 | 630 | 630 | 630 |
Estimated fuel (gas or diesel) used per hour |
35 | 160 | 200 | 210 |
Water supply |
1 bar 1/2 ' pipe |
1 bar 3/4 ' pipe |
1 bar 3/4 ' pipe |
1 bar 3/4 ' pipe |
Compressed air | 6 bars 0.8m3/H | 6 bars 0.8m3/H | 6 bars 1m3/H | 6 bars 1m3/H |
Size | ||||
Length (meters) | 3.50 | 5.50 | 7.25 | 9.65 |
Width (meters) | 1.35 | 1.75 | 2.02 | 2.02 |
Higher height (meters) | 1.90 | 3.30 | 3.35 | 3.35 |
Total weight (empty, metric tons) | 3 | 8 | 11 | 17 |
Possibility for airlight system between loading side and unloading side of dehydrator | yes |